Copper cable

Faster copper reaches less far

Categoryhow far a link can run at each speed (metres, to scale)0 m30 m55 m100 mCat 5e100 MHz1 GbpsCat 6250 MHz1 Gbps10 GbpsCat 6A500 MHz10 GbpsCat 82000 MHz25 Gbps40 GbpsFaster copper reaches less far: 10 Gbps needs Cat 6A for the full 100 metres, and Cat 8 manages 30.Every twisted-pair standard is written for a 100 m channel: 90 m of cable in the wall and 10 m of patch cords.Higher speeds use higher frequencies, which fade faster and leak more into the next pair. Cat 6 carries 10 Gbps onlyto 55 m. Cat 8 is for the few metres between switch and server inside a rack.

Twisted-pair cable is rated for 100 m. Cat 6A carries 10 Gbps all the way; Cat 6 only to 55 m.

Copper cable · Going deeper · 1 of 3

Inside the plug: pairs, pins and crossover

T568B, the usual wiring, looking into the plug1w/or2or3w/gr4bl5w/bl6gr7w/br8brPins 1, 2 send and 3, 6 receive at 10 and 100 Mbps.1 Gbps and faster use all four pairs in both directions.Straight-throughT568B at both ends: PC to switchCrossoverT568A at one end: 1↔3, 2↔6Auto-MDIXModern ports detect which pairs transmit and swap them,so either cable works. It is on by default on Cisco switches.Eight wires in four twisted pairs. The twist cancels interference; the pin order decides who talks on which pair.T568A and T568B differ only in swapping the orange and green pairs. A cable with the same standard at both ends isstraight-through. TX and RX transposed, or a pair split across two twists, shows up as errors or no link: a cabletester finds both. Untwisting more than about 13 mm at the plug causes crosstalk.

T568B is the usual pin order. Same standard at both ends gives a straight-through cable; Auto-MDIX makes crossover cables unnecessary.

Copper cable · Going deeper · 2 of 3

Ethernet names: speed, BASE, medium

StandardSpeedMediumReachNote100BASE-TX100 MbpsCat 5 copper100 mtwo pairs1000BASE-T1 GbpsCat 5e copper100 mfour pairs2.5G / 5GBASE-T2.5 / 5 GbpsCat 5e / Cat 6100 mfor Wi-Fi access points10GBASE-T10 GbpsCat 6A copper100 mCat 6: 55 m10GBASE-SR10 Gbpsmultimode fibre300 m (OM3)850 nm; 400 m on OM410GBASE-LR10 Gbpssingle-mode fibre10 km1310 nm100GBASE-SR4 / LR4100 GbpsMM 8 fibres / SM 2100 m / 10 kmQSFP28The name says it all: speed, BASE for one signal on the wire, then the medium.T means twisted-pair copper, S short-wave light on multimode fibre, L long-wave on single-mode, E extended. Theexams expect you to match each name to its medium and reach, and to choose the cheapest one that does the job.

1000BASE-T is 1 Gbps over twisted pair; 10GBASE-SR is 10 Gbps over multimode fibre; LR is single-mode to 10 km.

Copper cable · Going deeper · 3 of 3

Shielding and jackets: STP, plenum and riser

UTP and STPUTP: unshieldedoffices; most cableSTP: foil shieldnear motors, lights, radioThe jacket, and where it may runPlenum (CMP)in air-handling spaces: burns with low smokeRiser (CMR)up between floors: stops fire climbingGeneral (CM)everywhere else: cheapestThe shield keeps interference out; the jacket decides where building codes let the cable run.Interference (EMI) from motors and fluorescent ballasts, crosstalk between pairs, and attenuation over distance arethe three ways a copper signal degrades. Shielded cable must be grounded at the panel or the shield does nothing.Cable in a plenum, the air space above a ceiling, must be plenum-rated: it is a fire code requirement, not advice.

STP resists interference. A plenum-rated jacket is required in air-handling spaces.

Fibre

A thinner core carries light farther

Multimode50 µm core, 125 µm claddingSingle-mode9 µm core, 125 µm claddingcross-sections to scaleHow far 10 Gbps reaches (log scale)SR, OM3 multimode300 mSR, OM4 multimode400 mLR, single-mode10 kmER, single-mode40 kmA thinner core carries light farther: multimode reaches hundreds of metres, single-mode tens of kilometres.In a wide multimode core the light bounces along many paths that arrive at slightly different times, smearing the pulses.A single-mode core is so thin that one path is left. Multimode uses cheap 850 nm optics inside a building; single-modeuses 1310 or 1550 nm lasers between buildings and cities. Fibre ignores electrical interference completely.

Multimode fibre reaches hundreds of metres; single-mode fibre, with a 9 µm core, reaches tens of kilometres.

Fibre · Going deeper

Connectors: RJ45, LC, SC, ST, MPO and coax

ConnectorCarriesWhere you meet itRJ45twisted-pair Ethernet, 8 pinsevery desk, switch and access pointRJ11one or two phone pairs, 6 positionsanalogue phones, DSL linesLCfibre, small push-latch, usually as a pairSFP modules; the data-centre defaultSCfibre, square push-pullolder panels, fibre to the homeSTfibre, round bayonet twistold multimode installationsMPO / MTP12 or 24 fibres in one ferrule40G and 100G multimode links (SR4)F-type / BNCcoaxial cable, screw / bayonetcable broadband, older videoA fibre link is two strands, one each way, so connectors such as LC usually come in pairs.MPO carries many strands at once for parallel optics: 100GBASE-SR4 sends four lanes of 25 Gbps over eight fibres.Fibre ends must be clean; a speck of dust on a 9 µm core blocks the light. Inspect and clean before you blame the optic.

LC is the common fibre connector on modern optics; MPO carries 12 or 24 fibres for parallel 40G and 100G links.

Transceivers

The port is a socket; the module decides the medium and the speed

1 Gbps10 Gbps100 Gbps400 GbpsSFP1 lane1 GbpsSFP+1 lane10 GbpsSFP281 lane25 GbpsQSFP+4 lanes40 GbpsQSFP284 lanes100 GbpsQSFP-DD8 lanes400 GbpsSwitch portan empty socketModulechooses medium, reachThe port is only a socket. The module plugged into it decides the medium, the reach and often the speed.SFP-family modules carry one lane; QSFP (quad) carries four, and QSFP-DD eight. One switch can take a copper module, amultimode SR optic or a single-mode LR optic in neighbouring ports. Both ends of a link must use the same standard andwavelength: an SR optic will never talk to an LR optic. A direct-attach cable (DAC) has modules fused on, for a few metres.

An SFP module carries one lane; a QSFP carries four. Both ends of a link need matching optics.

Transceivers · Going deeper

Reading light levels on an optic

Received light on a 10GBASE-LR link, in dBm (each −3 dB halves the power)-20-15-10-502receiver works: −14.4 to +0.5 dBmtoo little lighthealthy: −3.1dirty connector: −16.8Read it on the switch with show interfaces transceiver: modules report temperature, voltage, and light sent and received.An optic that reports too little received light points to the fibre, not the module: dirt, a bend or a bad splice.Fibre loses about 0.35 dB per km at 1310 nm, and each connector pair about 0.5 dB, so a link budget adds up thelosses and checks they fit between what the sender transmits and what the receiver needs. A visual fault locatorshines red light down a strand so a break glows. An OTDR measures the distance to it.

Optics report received power in dBm. Below the receiver’s floor, about −14 dBm for 10GBASE-LR, look for dirt, bends or a bad splice.

Power over Ethernet

The cable delivers less power than the switch sends

watts per port: sent by the switch, and left at the device after the cable’s loss802.3afType 1 · phones, cameras15.4 W12.95 W802.3atPoE+, Type 2 · access points30 W25.5 W802.3btType 3 · PTZ cameras, Wi-Fi 760 W51 W802.3btType 4 · displays, lighting90 W71.3 WPower over Ethernet sends power down the data cable, and some of it is lost as heat on the way.The switch (the power sourcing equipment) checks for a valid signature before sending any power, so plugging a laptop inis safe. Types 1 and 2 use two pairs; 802.3bt uses all four. Losses grow with cable length and bundle size, which iswhy the device is guaranteed less than the port sends: 25.5 W of PoE+’s 30.

PoE gives 15.4 W per port, PoE+ 30 W and 802.3bt up to 90 W; the device receives less after cable loss.

Power over Ethernet · Going deeper

The power budget: why the last device stays dark

A 24-port switch with a 370 W PoE budget2 more APsbudget 370 W10 access points × 25.5 W + 8 cameras × 12.95 W = 358.6 WTwo more access points need 51 W and only 11.4 W is left, so the last one to ask is refused power.On Cisco IOS, show power inline lists each port’s class and draw, and the total available.Every port can offer PoE, but the switch’s power supply cannot feed every port at full power at once.24 ports at 30 W would need 720 W. A device that asks for power after the budget is spent stays dark, or comes upand drops out. “Power budget exceeded” and “wrong standard” (an 802.3bt device on a PoE+ port) are both Network+ faultscenarios. Devices announce their class through LLDP so the switch can reserve only what each needs.

A switch’s PoE budget is less than ports × 30 W. Once it is spent, the next device is refused power.

Distance and delay

Distance sets a floor on delay that no upgrade removes

the least possible round trip, set by the speed of light (log scale)1 µs10 µs100 µs1 ms10 ms100 ms1000 msAcross a building0.2 km · fibre2 µsLondon to New York5,570 km · fibre, great-circle56 msLow-orbit satellite550 km · up and down twice7 msGeostationary satellite35,786 km · up and down twice477 msDistance sets a floor on delay that no upgrade can remove. Bandwidth can be bought; the speed of light cannot.Light in fibre covers about 200 km every millisecond. Real paths are longer than the straight line and add queues,so London to New York measures about 70 ms, not 56. A geostationary satellite sits 35,786 km up and costs at least half asecond per round trip; low-orbit constellations fly at about 550 km and measure 25 to 60 ms.

Light in fibre covers about 200 km per millisecond, so London to New York can never be faster than about 56 ms there and back.

Lesson complete

You finished “Cables and connections”

Nicely done.