Copper cable
Faster copper reaches less far
Twisted-pair cable is rated for 100 m. Cat 6A carries 10 Gbps all the way; Cat 6 only to 55 m.
Most network cable is copper, in four twisted pairs, and every standard is written for a hundred-metre run. Category five e carries one gigabit the whole hundred metres. Category six does too, and it can carry ten gigabits, but only for fifty-five metres. Category six A carries ten gigabits the full hundred. Category eight goes to twenty-five or forty gigabits, but only for thirty metres, which is why you find it between a switch and the servers in the same rack. Higher speeds need higher frequencies, and higher frequencies fade faster.
Copper cable · Going deeper · 1 of 3
Inside the plug: pairs, pins and crossover
T568B is the usual pin order. Same standard at both ends gives a straight-through cable; Auto-MDIX makes crossover cables unnecessary.
Copper cable · Going deeper · 2 of 3
Ethernet names: speed, BASE, medium
1000BASE-T is 1 Gbps over twisted pair; 10GBASE-SR is 10 Gbps over multimode fibre; LR is single-mode to 10 km.
Copper cable · Going deeper · 3 of 3
Shielding and jackets: STP, plenum and riser
STP resists interference. A plenum-rated jacket is required in air-handling spaces.
Fibre
A thinner core carries light farther
Multimode fibre reaches hundreds of metres; single-mode fibre, with a 9 µm core, reaches tens of kilometres.
For longer runs, and for the highest speeds, networks use light in glass. Multimode fibre has a fat core, fifty micrometres across. Light bounces along it by many paths, and the pulses smear as they go. Single-mode fibre has a core of only nine micrometres, drawn here to scale. There is room for one path, so the pulses stay sharp. The result: ten gigabits over multimode reaches three or four hundred metres. Over single-mode, ten or forty kilometres.
Fibre · Going deeper
Connectors: RJ45, LC, SC, ST, MPO and coax
LC is the common fibre connector on modern optics; MPO carries 12 or 24 fibres for parallel 40G and 100G links.
Transceivers
The port is a socket; the module decides the medium and the speed
An SFP module carries one lane; a QSFP carries four. Both ends of a link need matching optics.
Switches for fibre do not have the optics built in. Each port is a socket for a small module. An SFP carries one gigabit, an SFP plus ten, an SFP twenty-eight twenty-five. The quad versions carry four lanes, and QSFP-DD eight: up to four hundred gigabits. The module chooses copper or fibre, multimode or single-mode, short or long reach. Mix them in neighbouring ports as you like, but both ends of one link must match.
Transceivers · Going deeper
Reading light levels on an optic
Optics report received power in dBm. Below the receiver’s floor, about −14 dBm for 10GBASE-LR, look for dirt, bends or a bad splice.
Power over Ethernet
The cable delivers less power than the switch sends
PoE gives 15.4 W per port, PoE+ 30 W and 802.3bt up to 90 W; the device receives less after cable loss.
The same cable can carry power. The first standard sends fifteen point four watts from the switch, of which almost thirteen reach the device: enough for a phone or a small camera. PoE plus sends thirty and guarantees twenty-five and a half, which most access points need. and The newer standard uses all four pairs to send sixty or ninety watts, for big cameras, the newest access points and even lighting. The gap between the two bars in each row is lost as heat in the cable.
Power over Ethernet · Going deeper
The power budget: why the last device stays dark
A switch’s PoE budget is less than ports × 30 W. Once it is spent, the next device is refused power.
Distance and delay
Distance sets a floor on delay that no upgrade removes
Light in fibre covers about 200 km per millisecond, so London to New York can never be faster than about 56 ms there and back.
There is one limit no money can lift. Across a building, a round trip takes a couple of microseconds. From London to New York, light in fibre needs at least fifty-six milliseconds there and back, and real paths measure about seventy. A low-orbit satellite, five hundred and fifty kilometres up, adds only a few milliseconds of travel. A geostationary satellite sits thirty-six thousand kilometres up, and every round trip costs at least half a second. That is why a video call over one feels so awkward.
Lesson complete
You finished “Cables and connections”
Nicely done.