Displays

Sharpness is pixels per inch, not resolution alone

ScreenPixels per inch24-inch, 1920 × 10809227-inch, 1920 × 10808227-inch, 2560 × 144010927-inch, 3840 × 21601636.1-inch phone, 2556 × 1179461Sharpness is pixels per inch, not resolution alone.Resolution counts the pixels. Pixel density divides them by the size of the screen. The same1920 × 1080 picture is coarser at 27 inches than at 24, and a phone packs in five times more.

Same resolution, bigger screen, lower pixel density.

Displays · Going deeper · 1 of 2

Panel types: IPS, TN, VA, Mini-LED, OLED

PanelHow it makes the pictureKnown forIPSLCD: crystals turn in the plane of the screenBest colour and wide viewing anglesTNLCD: crystals twistFast and cheap; colour shifts off-centreVALCD: crystals stand uprightDeepest blacks of the LCD typesMini-LEDLCD with thousands of small backlight LEDsBright, with dimming in zonesOLEDEach pixel is its own light; no backlightTrue black, thin; risk of burn-inEvery LCD needs a backlight. OLED does not.IPS, TN and VA are the three kinds of LCD. Mini-LED is an LCD with a better backlight.

IPS for colour, TN for speed, VA for contrast, OLED for black.

Displays · Going deeper · 2 of 2

Display terms

TermMeaningResolutionThe pixel count, width by height: 1920 × 1080, 3840 × 2160Pixel densityPixels per inch: resolution divided by screen sizeRefresh ratePictures drawn each second, in hertz: 60 Hz, 144 HzColour gamutThe range of colours the panel can show: sRGB, DCI-P3Touch screen / digitizerThe layer that senses a finger or a pen and reports whereInverterPowers the fluorescent backlight in older LCDs; LED backlights need noneA dim older laptop screen with a faint picture points to the inverter or the backlight.

Refresh rate, colour gamut, digitizer, inverter.

Network cables

Each category carries more over the same 100 metres

CableTop speed over 100 metres. Each mark is ten times the one before.10 Mbps100 Mbps1 Gbps10 GbpsCat 5100 MbpsCat 5e1 GbpsCat 61 Gbps; 10 Gbps up to 55 mCat 6a10 GbpsEach category of twisted-pair cable carries more over the same 100 metres.All four use the RJ45 plug and reach 100 metres. Cat 5e is the minimum for gigabit. Cat 6manages 10 gigabits on short runs only, and Cat 6a carries it the full distance.

Cat 5e for gigabit. Cat 6a for 10 gigabit at full length.

Network cables · Going deeper · 1 of 2

Shielding, jackets, coaxial and fibre

CableWhat it isWhereUTPUnshielded twisted pairOrdinary office runsSTPTwisted pair with a foil or braid shieldNear motors and electrical noisePlenumA jacket that resists fire and gives off little smokeAir spaces above ceilingsDirect burialA jacket sealed against water and soilUnderground, without a conduitCoaxialOne copper core inside a shield; F type plugCable internet and televisionSingle-mode fibreA very thin glass core; laser lightLong distance, kilometresMultimode fibreA wider core; cheaper light sourcesInside a building or campusOptical fibre carries light, so electrical interference cannot touch it.T568A and T568B are the two wire orders for an RJ45 plug. They swap the green and orangepairs. Use the same one at both ends; T568B is the common choice.

Plenum above ceilings. Single-mode for distance.

Network cables · Going deeper · 2 of 2

Connectors

ConnectorUsed forRecognise it byRJ45Ethernet twisted paireight pinsRJ11telephone line, DSLsmaller, up to six pinsF typecoaxial cablescrews onLCfibresmall, with a latchSCfibresquare, push and pullSTfibreround, twist to lockPunchdown blocktwisted pair in a wiring closet110 blockUSB-Cdata, video and poweroval, fits either way upmicroUSB / miniUSBolder phones and camerasone way up onlyLightningolder Apple deviceseight contactsDB9serial portnine pins, two screwsMolexpower inside the casefour pinsTwelve connectors. An adapter joins two of them without changing the signal.

RJ45, F type, LC, SC, ST, DB9, Molex.

Check yourself

Run60 m, through the air space above the ceilingSpeed10 GbpsRulethe fire code applies to that space

Which cable does this run need?

Peripheral cables

Thunderbolt carries about 83 times what USB 2.0 does

CableTop speed. Each mark is ten times the one before.10 kbps100 kbps1 Mbps10 Mbps100 Mbps1 Gbps10 Gbps100 GbpsSerial (DB9)115 kbpsUSB 2.0480 MbpsUSB 3.05 GbpsSATA6 GbpsThunderbolt 3 and 440 GbpsThunderbolt carries about 83 times what USB 2.0 does.Serial is the old nine-pin port, still used to configure switches. USB 3.0 ports are usually blue.SATA joins drives inside the case, and eSATA is the same link outside it.

USB 2.0 480 Mbps, USB 3.0 5 Gbps, Thunderbolt 40 Gbps.

Peripheral cables · Going deeper

Video cables

CableSignalCarries soundNoteVGAAnalogueNo15 pins, blue, two screwsDVIDigital; some carry analogueNoWhite, wide, two screwsHDMIDigitalYesTVs, monitors, projectorsDisplayPortDigitalYesLocks in; common on PCsUSB-CDigitalYesOnly if the port supports videoThunderboltDigitalYesUSB-C plug with a lightning markVGA is the only analogue one, so it is the one that looks soft on a sharp screen.Not every USB-C port carries video. A Thunderbolt port always does.

VGA is analogue. HDMI and DisplayPort carry sound.

Memory

A module must match the slot twice: size and generation

DIMMdesktops and servers · 133 mm · 288 pins for DDR4 and DDR5SODIMMlaptops and small PCs · 70 mmthe gap in the contacts sits in a different place for DDR3, DDR4 and DDR5A memory module must match the slot twice: by size and by generation.A DIMM is twice the length of a SODIMM. Within each size, DDR3, DDR4 and DDR5 are keyeddifferently, so the wrong generation will not go in. Check what the motherboard takes.

DIMM or SODIMM. Then DDR3, DDR4 or DDR5.

Memory · Going deeper

Pin counts, ECC and channels

GenerationDIMM pinsSODIMM pinsFits another generationDDR3240204NoDDR4288260NoDDR5288262NoTermMeaningECCExtra bits find and correct a single-bit error. Servers and workstations.Non-ECCNo correction. Ordinary desktops and laptops.Single channelOne module, or modules in the wrong slots: one path to memory.Dual channelA matched pair in the paired slots: two paths, more throughput.Triple, quad channelThree or four matched modules, on workstation and server boards.For dual channel, follow the slot colours or the manual: usually slots 2 and 4.

ECC corrects errors. Dual channel needs a matched pair.

Check yourself

Computera laptopManualtwo slots, DDR4In stockDDR4 DIMM, DDR4 SODIMM, DDR5 SODIMM

Which memory does this computer take?

Drive arrays

RAID trades drive space for drives you can lose

LevelFewest drives, 4 TB eachYou can useDrives it can loseHowRAID 08 of 8 TBnonestripingRAID 14 of 8 TB1mirroringRAID 58 of 12 TB1striping with parityRAID 68 of 16 TB2double parityRAID 108 of 16 TB1a stripe of mirrorsspace you can usespace spent on protectionRAID trades drive space for the number of drives you can lose.RAID 0 is fast and keeps every gigabyte, but one failure loses everything. RAID 10 isguaranteed to survive one failure, and survives two when they fall in different mirrors.

RAID 0 none. RAID 1 and RAID 5 one. RAID 6 two.

Drive arrays · Going deeper

Drives, interfaces and form factors

StorageConnects byRememberHard drive (HDD)SATA; SAS in servers5,400, 7,200, 10,000 or 15,000 rpm; 3.5 or 2.5 inchSATA SSDSATA, 6 Gbps2.5 inch, or M.2 and mSATA cardsNVMe SSDPCIeM.2 card; several times faster than SATAFlash driveUSBPortable; easy to loseMemory cardA card readerSD and microSD in cameras and phonesOptical discSATA or USB driveCD 700 MB, DVD 4.7 GB, Blu-ray 25 GBM.2 is a shape, not a speed: an M.2 card may be SATA or NVMe.Check the key notches and what the slot supports. Faster platters mean a faster, hotter, louder drive.

NVMe over PCIe. M.2 is a shape, not a speed.

Check yourself

Drivesfour, 4 TB eachMustkeep working if any two drives failWantsas much usable space as that allows

Which RAID level fits?

Lesson complete

You finished “Displays, cables, memory and storage”

Answer the questions along the way to see your score here.

Open in a new tab